Eltek Flatpack2 380V Rectifier Module 3000W HE UI 241119.825

Brand Name : Eltek

Model Number : 241119.825

Certification : CE

Place of Origin : China

MOQ : 1

Price : 370USD

Payment Terms : T/T

Supply Ability : 200pcs/month

Delivery Time : 1 week

Packaging Details : Original Packed by Carton

Brand : Eltek

Part number : 241119.825

Country of Origin : China

Contact Now

Eltek Flatpack2 380V Rectifier Module 3000W HE UI 241119.825

  • HE rectifier for 380VDC in data centers
  • The Flatpack2 380/3000 HE UI rectifier has high efficiency, ORing protection on output and high output power.
  • Distribute pure battery backup DC voltage with a minimum of loss. Remove the low reliable DC-AC step in the central backup power system and maximize its reliability and efficiency.
  • Stack cabinets with up to 72 rectifiers to build large power systems monitored by the Smartpack2 controller.
  • The rectifiers Universal Input also allows it being powered from the 380Vdc bus. Static voltage outputs (300-400Vdc) can be realized for 400Vdc remote powering and other applications.

Technical Specifications - FLATPACK2 380V RECTIFIER
Model Flatpack2 380/3000HE UI
Part number 241119.825
INPUT DATA
Voltage range (nominal) 176 - 277 VAC / 260 - 400 VDC1)
Voltage (operating range) 85 - 305 VAC / 260 - 410 VDC1)
Frequency 45 - 66 Hz / 15 - 18.5 Hz2) / DC1)
Maximum current 18.2 ARMS
Power Factor 0.99 (@ 50-100% load)
Protection Fuse in both lines, varistor for transient protection, shutdown when VIN is out of range
OUTPUT DATA
Default voltage 381 VDC
Voltage range 300 - 400 VDC
# Pb cell supported 156 - 168 3)
Max power, nominal input 3000 W (@VOUT ≥ 48VDC)
Power (maximum) @ 85 VDC / 85 VAC input 1200 W
Current continuous (maximum) 9 A (@VOUT < 336 VDC) / 7.9 A (@ VOUT = 381 VDC)
Hold-up time, default voltage and 1000 W load > 20 ms; output voltage > 300 VDC at 1500 W load
Current sharing (10 - 100% load) ± 5% of maximum current
Static Voltage regulation (10 - 100% load) ±0.5%
Static voltage regulation ±0.5% for 10 - 100% load
Dynamic voltage regulation ±2.0% for 10-90% or 90-10% load variation, regulation time < 10 ms 5)
Ripple < 1000 mVP-P , 30 MHz bandwidth
Protection Overvoltage shutdown, Hot plug-in - Inrush current limiting, ORing diode, Fuse5), Short circuit proof, High temperature protection, Overload shutdown4)
OTHER SPECIFICATIONS
Efficiency @ 230 VAC / 380VDC input 96.2% / 96.6%
Isolation 3.0 kVAC – input to output, 1.5 kVAC – input to earth, 1.5 kVDC – output to earth,
3.0 kVAC – CAN to primary, 3.0 kVAC – CAN to secondary
Alarms (Red LED) Low mains shutdown, High and low temperature shutdown, Rectifier Failure,Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure
Warnings (Yellow LED) Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage
Normal (Green LED) Input and output ok
Acoustic noise, at nominal input and full load < 40dBA @Tambient< 25°C / <58dBA @ Tambient> 40°C
MTBF (Telcordia SR-332 Issue I method III (a)) 2 291 210h (@ Tambient = 25 °C)
Operating temperature (5 - 95% RH non-cond.) Output power de-rates above temp / to -40 to +75°C (-40 to +167°F), humidity 5 - 95% RH non-condensing
Output power de-rates linear from 3000W @ 50°C (122°F) to 980W @ 75°C(167°F)
Storage temperature -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
Dimensions[WxHxD] / Weight 109 x 41.5 x 327 mm (4.25 x 1.69 x 13”) / < 1.95 kg (4.3 lbs)
DESIGN STANDARDS
Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013, UL
60950-1:2014, CSA C22.2 No. 60950-1-07
EMC EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010,
IEC61000-6-5: 2015, EN 300 386:v1.6.1, FCC CFR 47 Part 15:2013
Environment Tested according to: ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)
Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating
conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised
2011/65/EU (RoHS) & 2012/19/EU (WEEE)

Eltek Flatpack2 380V Rectifier Module 3000W HE UI 241119.825


Product Tags:

241119.825 Rectifier Module

      

3000W Eltek Flatpack2 Rectifier Module

      

Eltek Flatpack2 380V Rectifier Module

      
Quality Eltek Flatpack2 380V Rectifier Module 3000W HE UI 241119.825 for sale

Eltek Flatpack2 380V Rectifier Module 3000W HE UI 241119.825 Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing Guoguang Xingda Technology Co.,ltd
*Subject:
*Message:
Characters Remaining: (0/3000)